HECS storage tanks: filament wound FRP tanks and SMC panel tanks

In short: HECS makes filament wound FRP tanks (seamless, factory-built, for above- or below-ground installation) and SMC panel tanks (modular, assembled on site, 10 m³ to 5,000 m³) for potable water, fire water, chemicals, oil and wastewater. Made at our 2.5-acre factory at SIPCOT Vallam Vadagal, Sriperumbudur, Chennai.

Corrosion-resistant · no liners or coatings neededInstalled in a couple of days · factory-finished, minimal site workAbove or below ground · rooftop, basement, sump or under traffic load
HECS FRP water storage tank: corrosion resistant, high strength, long service life
HECS filament wound FRP storage tank
Product 1
Filament wound FRP storage tanks
SeamlessFactory-built, no joints
2 daysTypical installation
Above / belowGround installation
No linersCorrosion-resistant, no coatings
See FRP tank benefits
Product 2
SMC panel tanks
10–5,000 m³Capacity; larger by separate design
1.0–5.0 mPossible tank height
40 yearsDesign life of SMC material
Cube, L, UCorner and odd-shaped layouts
See SMC tank benefits

Two tank technologies, one supplier

HECS filament wound FRP storage tanks at the factory
HECS filament wound FRP tanks
Product line 1
Filament wound FRP tanks

What is a filament wound FRP tank? A seamless tank made by winding resin-soaked glass fibre on a mandrel in the HECS factory. The result is uniform strength, no joints, and a tank that is unaffected by UV, heat or biological growth.

  • Seamless, factory-built at our Chennai plant
  • Above- or below-ground installation
  • Corrosion-resistant, no liners or coatings needed
  • Installed in a couple of days
Get a FRP tank quote
HECS SMC panel water tank installed on site
HECS SMC panel tank installed on site
Product line 2
SMC panel tanks

What is an SMC panel tank? A modular tank built on site from hot-pressed SMC (sheet moulding compound) panels. The panels block light, algae and germs, and special sealing tape keeps the tank watertight.

  • 10 m³ to 5,000 m³ capacity, 1.0–5.0 m high
  • Cube, corner and odd-shaped (L, U) layouts
  • Assembled on site, relocatable
  • 40-year design life of SMC material
Get a SMC tank quote

Filament wound FRP tank or SMC panel tank?

Filament wound FRP tankSMC panel tank
ConstructionSeamless; resin-soaked fibre wound on a mandrelModular hot-pressed panels, assembled on site
CapacitySized to your project10 m³ to 5,000 m³; larger tanks by separate design
HeightAs designed1.0 m to 5.0 m
InstallationAbove or below ground; installed in a couple of daysRooftop, basement or ground; easy to assemble and relocate
ShapesHorizontal or vertical cylinderCube, corner and odd-shaped (L, U) layouts
Best forUnderground sumps, sewage and chemical storage, sites needing a ready tankLarge reserve tanks, rooftops and basements with narrow access
HygieneNon-porous; no liners neededPanels block light, algae and germs
Design lifeLong life; unaffected by UV, heat or biological growth40-year design life of SMC material

Not sure which suits you? Share the use, volume and space, and we will recommend the type and size.

SMC panel tank sizes: 10 m³ to 5,000 m³

1 m³ = 1 KL = 1,000 litres. SMC tank volume is length × width × height; panels of different sizes let us fit the tank to your space, at heights from 1.0 m to 5.0 m. Example layouts:

CapacityLitresTypical useExample size (L × W × H)
10 m³10,000Villas, small offices, treated water from a 10 KLD STP3 × 2 × 2 m (12 m³)
50 m³50,000Apartments, hotels, hospitals, fire water reserve4 × 4 × 3 m (48 m³)
100 m³1,00,000Gated communities, IT parks, factories6 × 6 × 3 m (108 m³)
500 m³5,00,000Townships, campuses, industrial process water12 × 10 × 4 m (480 m³)
1,000 m³10,00,000Large industry, municipal reserves16 × 16 × 4 m (1,024 m³)
5,000 m³50,00,000Very large reserves; larger by separate design32 × 32 × 5 m (5,120 m³)

Tip for STP treated water: store at least one day of output, so a 50 KLD STP needs about a 50 m³ tank. Estimate your daily flow with the capacity calculator.

Not sure which size you need? Share your daily use or site space and we will size the tank for you.
Get my tank size

Built for every kind of liquid storage

Water storagepotable, waste and process water.
Firewater storagea reliable reserve for fire suppression.
Oil and gasfuels, oils and petrochemicals.
Chemical storageacids, alkalis and solvents.
Marinesaltwater-resistant holding tanks.
Wastewater treatmentstorage, treatment and reuse, with our packaged sewage treatment plant.
One project, five storage needs. HECS supplies tanks for every one of these, above or below ground.
1Overhead water storage
2Fire water storage
3Sewage collection & treatment
4Raw water sump
5Rainwater collection / dewatering
HECS FRP storage tanks installed above ground at a project site
HECS FRP tanks installed above ground

Filament wound FRP tanks: strong, seamless and built to last

Build qualityresin-soaked fibre wound on a mandrel for uniform strength.
Cost-effectivelower life-cycle cost than concrete.
Durabilityunaffected by UV, heat or biological growth.
Easy installationinstalled in a couple of days.
Lower impactlower environmental impact in manufacture.
Corrosion resistanceno liners or coatings needed.
HECS filament winding machine making an FRP tank
Filament winding at the HECS factory

Civil (RCC) tank vs HECS FRP tank

AspectCivil (RCC) tankHECS filament wound FRP tank
Installation timeLong, labour-intensive, needs curingQuick, factory-finished, minimal site work
Strength and durabilityStrong in compression, cracks over timeHigh tensile strength, crack-resistant
Corrosion resistanceMoisture and chemical degradationExcellent chemical and corrosion resistance
MaintenanceFrequent sealing, patching, repairsVery low maintenance
Cost efficiencyLower initial cost, higher long-term costHigher upfront cost, lower life-cycle cost

More in our comparison FRP vs RCC.

Replacing or avoiding a concrete tank? Get an FRP tank that installs in days, not weeks.
Compare with my RCC quote

SMC panel tanks: hygienic, watertight and modular

Large capacityideal for large underground reserve tanks.
Hygiene and durabilityhot-pressed panels block light, algae and germs.
Free capacity designpanels of various sizes fit any space.
Perfect watertightnessspecial sealing tape with excellent recovery.
Simple assemblyeasy to assemble and relocate.
High quality40-year design life of SMC material.
Layouts & locations
CubeCornerL-shapeU-shapeRooftopBasementUndergroundAbove ground
HECS SMC panel water tank installed on site
HECS SMC panel tank installed on site

Ten reasons to choose HECS tanks

01Easy and quick installation
02Custom manufacturing
03100% hygienic, suitable for water
04Durable and cost-effective
05Low maintenance cost
06Space-saving; can sit under traffic load
07Can be re-installed and relocated
08100% rust-proof
09Lightweight for hard-to-reach sites
10Non-porous: no contamination
Robust structure: integrally cast ribs and dished-end design give excellent strength.
Ready to choose your tank? FRP or SMC, above or below ground: get a recommendation and quote.
Get a tank quote
About HECS
25+years in water & environment
₹300 Cr+annual turnover
30+partner dealers
5+countries, pan-India coverage
2.5 acrestank factory, Sriperumbudur

Tanks are made at our 2.5-acre facility at SIPCOT Vallam Vadagal, Sriperumbudur, Chennai, with filament winding, a dedicated factory floor and in-house dispatch. Head office: TVK Industrial Estate, Guindy, Chennai.

HECS FRP tank factory at SIPCOT Vallam Vadagal, Sriperumbudur
Our tank factory, Sriperumbudur
HECS FRP tank installed below ground
FRP tank installed below ground

How we supply and install your tank

1
Share your needliquid, volume, site photos and space.
2
Get a recommendation and quoteFRP or SMC, size, layout and fittings.
3
Site preparationa level base for above-ground tanks, or the excavation for below-ground tanks, as per our drawing.
4
DeliveryFRP tanks arrive finished from the factory; SMC panels arrive ready to assemble.
5
Installation and leak testour team installs, assembles and fills the tank to test it.
6
Handoverdocumentation and care tips.
Step 1 takes two minutes. Tell us the liquid, volume and site, and an HECS engineer will reply.
Start my enquiry
HECS FRP tank loaded on a trailer for dispatch from the factory
Ready for dispatch from the HECS factory
Enquiry

Get a size and quote for your FRP or SMC tank

Tell us about your requirement and an HECS engineer will reply with a recommended tank type, size and layout. Helpful to include:

Size at a glance: 1 m³ = 1,000 litres. SMC tanks: 10 m³ to 5,000 m³, 1.0–5.0 m high. For treated water, plan at least one day of STP output.

Prefer to talk?

Hubert Enviro Care Systems, A21, 3rd Phase, TVK Industrial Estate, Guindy, Chennai 600032. Your details are used only to respond to this enquiry.

FAQs

FRP and SMC storage tanks: common questions

Can’t find your answer? Ask an HECS engineer. We reply within minutes.

A filament wound FRP tank is a seamless tank made in the HECS factory by winding resin-soaked glass fibre on a mandrel. An SMC panel tank is assembled on site from hot-pressed panels, so its size and shape can fit any space.

From 10 m³ to 5,000 m³, at heights from 1.0 m to 5.0 m. Larger tanks are possible by separate design.

Yes. Filament wound FRP tanks are installed above or below ground, and can be designed to sit under traffic load.

Yes. HECS tanks are 100% hygienic and suitable for water, non-porous, and the SMC panels block light, algae and germs.

FRP tanks are unaffected by UV, heat or biological growth and do not rust. SMC material has a 40-year design life.

A filament wound FRP tank is factory-finished and installed in a couple of days. SMC tanks are simple to assemble on site.

Potable, waste and process water, fire water, fuels and oils, acids, alkalis and solvents, saltwater, and wastewater.

FRP costs more upfront but less over its life: it installs quickly, resists cracks and corrosion, and needs very little maintenance, while RCC needs curing and frequent repairs.

Need a water, fire or chemical storage tank?

Filament wound FRP or SMC panel, above or below ground. Tell us the liquid and volume, and get a recommendation and quote from HECS.

FRP Water Storage Tanks & SMC Panel Tanks